15 research outputs found

    Clinical applications of ultra-high field magnetic resonance imaging in multiple sclerosis

    Get PDF
    Introduction: Magnetic resonance imaging (MRI) is of paramount importance for the early diagnosis of multiple sclerosis (MS) and MRI findings are part of the MS diagnostic criteria. There is a growing interest in the use of ultra-high-field strength 127 Tesla- (7T) MRI to investigate, in vivo, the pathological substrate of the disease. Areas covered: An overview of 7T MRI applications in MS focusing on increased sensitivity for lesion detection, specificity of the central vein sign and better understanding of MS pathophysiology. Implications for disease diagnosis, monitoring and treatment planning are discussed. Expert commentary: 7T MRI provides increased signal-to-noise and contrast-to-noise-ratio that allow higher spatial resolution and better detection of anatomical and pathological features. The high spatial resolution reachable at 7T has been a game changer for neuroimaging applications not only in MS but also in epilepsy, brain tumors, dementia, and neuro-psychiatric disorders. Furthermore, the first 7T device has recently been cleared for clinical use by the food and drug administration

    The relationship between cortical lesions and periventricular NAWM abnormalities suggests a shared mechanism of injury in primary-progressive MS.

    Get PDF
    In subjects with multiple sclerosis (MS), pathology is more frequent near the inner and outer surfaces of the brain. Here, we sought to explore if in subjects with primary progressive MS (PPMS) cortical lesion load is selectively associated with the severity of periventricular normal appearing white matter (NAWM) damage, as assessed with diffusion weighted imaging. To this aim, twenty-four subjects with PPMS and twenty healthy controls were included in the study. Using diffusion data, skeletonized mean diffusivity (MD) NAWM maps were computed excluding WM lesions and a 2 mm-thick peri-lesional rim. The supra-tentorial voxels between 2 and 6 mm of distance from the lateral ventricles were included in the periventricular NAWM mask while the voxels between 6 and 10 mm from the lateral ventricles were included in the deep NAWM mask; mean MD values were then computed separately for these two masks. Lastly, cortical lesions were assessed on phase-sensitive inversion recovery (PSIR) images and cortical thickness was quantified on volumetric T1 images. Our main result was the observation in the PPMS group of a significant correlation between periventricular NAWM MD values and cortical lesion load, with a greater cortical lesion burden being associated with more abnormal periventricular NAWM MD. Conversely, there was no correlation between cortical lesion load and deep NAWM MD values or periventricular WM lesions. Our data thus suggest that a common - and relatively selective - factor plays a role in the development of both cortical lesion and periventricular NAWM abnormalities in PPMS

    An MRI evaluation of grey matter damage in African Americans with MS

    Get PDF
    Objective: Multiple sclerosis (MS) is less prevalent in African Americans (AAs) than Caucasians (CAs) but in the former the disease course tends to be more severe. In order to clarify the MRI correlates of disease severity in AAs, we performed a multimodal brain MRI study to comprehensively assess the extent of grey matter (GM) damage and the degree of functional adaptation to structural damage in AAs with MS. Methods: In this cross-sectional study, we characterized GM damage in terms of focal lesions and volume loss and functional adaptation during the execution of a simple motor task on a sample of 20 AAs and 20 CAs with MS and 20 healthy controls (CTRLs). Results: In AAs, we observed a wider range of EDSS scores than CAs, with multisystem involvement being more likely in AAs (p < 0.01). While no significant differences were detected in lesion loads and global brain volumes, AAs showed regional atrophy in the posterior lobules of cerebellum, temporo-occipital and frontal regions in comparison with CAs (p < 0.01), with cerebellar atrophy being the best metric in differentiating AAs from CAs (p = 0.007, AUC = 0.96 and p = 0.005, AUC = 0.96, respectively for right and left cerebellar clusters). In AAs, the functional analysis of cortical activations showed an increase in task-related activation of areas involved in high level processing and a decreased activation in the medial prefrontal cortex compared to CAs. Interpretation: In our study, the direct comparison of AAs and CAs points to cerebellar atrophy as the main difference between subgroups

    Clinical applications of ultra-high field magnetic resonance imaging in multiple sclerosis.

    No full text
    ntroduction: Magnetic resonance imaging (MRI) is of paramount importance for the early diagnosis of multiple sclerosis (MS) and MRI findings are part of the MS diagnostic criteria. There is a growing interest in the use of ultra-high-field strength -7Tesla- (7T) MRI to investigate, in vivo, the pathological substrate of the disease.Areas covered: An overview of 7T MRI applications in MS focusing on increased sensitivity for lesion detection, specificity of the central vein sign and better understanding of MS pathophysiology. Implications for disease diagnosis, monitoring and treatment planning are discussed.Expert commentary: 7T MRI provides increased signal-to-noise and contrast-to-noise-ratio that allow higher spatial resolution and better detection of anatomical and pathological features. The high spatial resolution reachable at 7T has been a game changer for neuroimaging applications not only in MS but also in epilepsy, brain tumors, dementia, and neuro-psychiatric disorders. Furthermore, the first 7T device has recently been cleared for clinical use by the food and drug administration

    Sodium MRI of multiple sclerosis.

    No full text
    Multiple sclerosis (MS) is the most common cause of non-traumatic disability in young adults. The mechanisms underlying neurodegeneration and disease progression are poorly understood, in part as a result of the lack of non-invasive methods to measure and monitor neurodegeneration in vivo. Sodium MRI is a topic of increasing interest in MS research as it allows the metabolic characterization of brain tissue in vivo, and integration with the structural information provided by (1)H MRI, helping in the exploration of pathogenetic mechanisms and possibly offering insights into disease progression and monitoring of treatment outcomes. We present an up-to-date review of the sodium MRI application in MS organized into four main sections: (i) biological and pathogenetic role of sodium; (ii) brief overview of sodium imaging techniques; (iii) results of sodium MRI application in clinical studies; and (iv) future perspectives

    Brain intra- and extracellular sodium concentration in multiple sclerosis: a 7 T MRI study.

    No full text
    Intra-axonal accumulation of sodium ions is one of the key mechanisms of delayed neuro-axonal degeneration that contributes to disability accrual in multiple sclerosis. In vivo sodium magnetic resonance imaging studies have demonstrated an increase of brain total sodium concentration in patients with multiple sclerosis, especially in patients with greater disability. However, total sodium concentration is a weighted average of intra- and extra-cellular sodium concentration whose changes reflect different tissue pathophysiological processes. The in vivo, non-invasive measurement of intracellular sodium concentration is quite challenging and the few applications in patients with neurological diseases are limited to case reports and qualitative assessments. In the present study we provide first evidence of the feasibility of triple quantum filtered (23)Na magnetic resonance imaging at 7 T, and provide in vivo quantification of global and regional brain intra- and extra-cellular sodium concentration in 19 relapsing-remitting multiple sclerosis patients and 17 heathy controls. Global grey matter and white matter total sodium concentration (respectively P < 0.05 and P < 0.01), and intracellular sodium concentration (both P < 0.001) were higher while grey matter and white matter intracellular sodium volume fraction (indirect measure of extracellular sodium concentration) were lower (respectively P = 0.62 and P < 0.001) in patients compared with healthy controls. At a brain regional level, clusters of increased total sodium concentration and intracellular sodium concentration and decreased intracellular sodium volume fraction were found in several cortical, subcortical and white matter regions when patients were compared with healthy controls (P < 0.05 family-wise error corrected for total sodium concentration, P < 0.05 uncorrected for multiple comparisons for intracellular sodium concentration and intracellular sodium volume fraction). Measures of total sodium concentration and intracellular sodium volume fraction, but not measures of intracellular sodium concentration were correlated with T2-weighted and T1-weighted lesion volumes (0.05 < P < 0.01) and with Expanded Disability Status Scale (P < 0.05). Thus, suggesting that while intracellular sodium volume fraction decrease could reflect expansion of extracellular space due to tissue loss, intracellular sodium concentration increase could reflect neuro-axonal metabolic dysfunction

    Measurement of glomerular filtration rate by dynamic contrast-enhanced magnetic resonance imaging using a subject-specific two-compartment model

    Full text link
    Measuring glomerular filtration rate (GFR) by dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) as part of standard of care clinical MRI exams (e.g., in pediatric solid tumor patients) has the potential to reduce diagnostic burden. However, enthusiasm for this relatively new GFR test may be curbed by the limited amount of cross-calibration studies with reference GFR techniques and the vast variety of MR tracer model algorithms causing confusion on the choice of model. To advance MRI-based GFR quantification via improved GFR modeling and comparison with associated 99mTc-DTPA-GFR, 29 long-term Wilms' tumor survivors (19.0-43.3 years, [median 32.0 ± 6.0 years]) treated with nephrectomy, nonnephrotoxic chemotherapy ± radiotherapy underwent MRI with Gd-DTPA administration and a 99mTc-DTPA GFR test. For DCE-MRI-based GFR estimation, a subject-specific two-compartment (SS-2C) model was developed that uses individual hematocrit values, automatically defines subject-specific uptake intervals, and fits tracer-uptake curves by incorporating these measures. The association between reference 99mTc-DTPA GFR and MR-GFRs obtained by SS-2C, three published 2C uptake, and inflow-outflow models was investigated via linear regression analysis. Uptake intervals varied from 64 sec to 141 sec [96 sec ± 21 sec] and hematocrit values ranged from 30% to 49% [41% ± 4%]; these parameters can therefore not be assumed as constants in 2C modeling. Our MR-GFR estimates using the SS-2C model showed accordingly the highest correlation with 99mTc-DTPA-GFRs (R2 = 0.76, P < 0.001) compared with other models (R2-range: 0.36-0.66). In conclusion, SS-2C modeling of DCE-MRI data improved the association between GFR obtained by 99mTc-DTPA and Gd-DTPA DCE-MRI to such a degree that this approach could turn into a viable, diagnostic GFR assay without radiation exposure to the patient
    corecore